Room Air ConditionerService and PartsManualKP Line KP05 / KP06 (03/03)KP05A10 KP06A10
2.4.2 EVAPORATOR1. Remove the cabinet.2. Discharge the refrigerant by using a refrigerantrecovery system.3. Remove the air guide upper. (Refer to Sect
—11—Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment, pinch-off tool capableof making a vapor proof seal, leak dete
—12—3. INSTALLATION This air conditioner is designed with a button-downchassis so it can be easily installed in a window. 3.1 SELECT THE BEST LOCATION
—13—Installation3.2.2 BEFORE INSTALLATION1. Insert the guide panels into the guides of the air condi-tioner. Fasten the curtains to the unit with scre
3. INSTALL THE AIR CONDITIONER IN THE WINDOWa. Carefully lift the air conditioner and slide it into theopen window. Make sure the bottom guide of the
—15—REMOVAL FROM WINDOWTurn the air conditioner off, disconnect the power cord, remove the L bracket and the screws installed through the top and bot-
—16—4.2 PIPING SYSTEMFollowing is a brief description of the important components and their function in what is called the refrigerationsystem. Refere
—17—4.3 TROUBLESHOOTING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused by an electr
—18—Fails to Start Improper thermostat setting Loose terminal connection Improper wiring Check of power source. Drop of power voltage. Capacitor check
COMPLAINT CAUSE REMEDY Fan motor will not run. No power Check voltage at outlet. Correct if none. Power supply cord Check voltage to rotary switch
—2—CONTENTS 1. PREFACE ...
—20—COMPLAINT CAUSE REMEDY Fan motor noise. Fan If cracked, out of balance, or partially missing, replace it. Blower If cracked, out of balance,
—21—COMPLAINT CAUSE REMEDY Compressor cycles on Fan motor If not running, determine the cause. Replace if overload. required. Condenser air flow R
—22—5. CIRCUIT DIAGRAM WH(BL)POWER INPUTBK(BR)(Ribbed) (Plain)GN/YL(GN)GN/YL(GN)THERMISTORBK BKBLRDBLRDCN-TH1YL YLOR(BR) OR(BR)ORSYNCMOTORRY-LORY-HICN
—23—6. EXPLODED VIEW352390130410359012W48602354210349480352390-1149980559011346811554030W4860213091055014055416056750235211555210235211135211335211A13
—24—7. SERVICE PARTS LIST • KP05A10, KP06A10130410 BASE ASSEMBLY,SINGLE 3041A10011F 67302906 R130910 CABINET ASSEMBLY,SINGLE 3091A10020A 67303704 R135
—25—MEMO
—26—MEMO
KP05 / KP06 (03/03)Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480FRIEDRICH AI
—3—1. PREFACE This service manual provides various service information, including the mechanical and electrical parts, etc. This room air conditioner
—4—1.3 LOCATIONS OF CONTROLS 1.4 SAFETY PRECAUTIONS 1. When servicing, set the ROTARY SWITCH to Off and unplug the power cord. 2. Observe the original
—5—2. DISASSEMBLY INSTRUCTIONS 2.1 MECHANICAL PARTS 2.1.1 FRONT GRILLE 1. Pull the inlet grille forward.2. Remove the screw securing the Front Grille.
—6—2.2 AIR HANDLING PARTS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 2.1.1)3.
—7—2.2.3 MOTOR1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 2.1.1)3. Remove the cabinet. (Refer to Sectio
—8—2.3.2 COMPRESSOR 1. Remove the front grille and cabinet. (Refer to Section 2.1) 2. Discharge the refrigerant by using a refrigerantrecovery system.
—9—2.3.6 POWER CORD1. Disconnect the unit from source of power.2. Remove the front grille. (Refer to Section 2.1.1)3. Remove the cabinet. (Refer to Se
Comentarios a estos manuales