Friedrich SH20J30B-A Manual de usuario

Busca en linea o descarga Manual de usuario para Acondicionadores de aire del sistema de división Friedrich SH20J30B-A. Friedrich SH20J30B-A User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
AMERICA’S BEST AIR CONDITIONER
2002
HAZARDGARD
®
ROOM AIR CONDITIONER
Service & Parts
Manual
Models
SH14J30B-A
SH20J30B-A
HG2002 (02/02)
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - HAZARDGARD

AMERICA’S BEST AIR CONDITIONER2002HAZARDGARD®ROOM AIR CONDITIONERService & PartsManualModelsSH14J30B-ASH20J30B-AHG2002 (02/02)

Pagina 2 - TABLE OF CONTENTS

10NOTE:All inoperative compressors returned toFriedrich must have all lines properly pluggedwith the plugs from the replacementcompressor.REFRIGERANT

Pagina 3 - SH14J30B-A SH20J30B-A

11PROBLEM POSSIBLE CAUSE TO CORRECTUnit does notrun.PROBLEM POSSIBLE CAUSE TO CORRECTDirty Filter.Restricted air flow.Inoperative thermostat.Short of

Pagina 4 - FIGURE 1 INTERNAL OVERLOAD

12PROBLEM POSSIBLE CAUSE TO CORRECTCompressorattempts tostart, or runsfor shortperiods only.Cycles onoverload.Allow a minimum of two (2) minutes to al

Pagina 5

13PROBLEM POSSIBLE CAUSE TO CORRECTReplace selector switch. Replace relay.Selector Switch RelayPROBLEM POSSIBLE CAUSE TO CORRECTRefer to Installation

Pagina 6 - COMPRESSOR

14WIRING DIAGRAM FOR SH14J30B-A & SH20J30B-A

Pagina 7 - (More Follows)

15HazardGard Cabinet Parts

Pagina 8

16HazardGard Chassis Parts

Pagina 9

17HAZARDGARD PARTS LISTREF. PART NO. DESCRIPTION APPLICATIONSSHH1240JJ3300BB--AA1 611-935-49 Compressor, Tecumseh, 230/208V; 60 Hz 1 Ph, Model AWG551

Pagina 10

18HAZARDGARD PARTS LISTREF. PART NO. DESCRIPTIONSSHH1240JJ3300BB--AAAPPLICATION14 618-028-02 Partition, Control Box ...

Pagina 11

19* 618-092-00 Lever, Fresh Air & Exhaust ... 1 1*

Pagina 12

2TABLE OF CONTENTSSpecifications ...

Pagina 13

20Friedrich Air Conditioning Co.4200 North Pan Am ExpresswayP.O. Box 1540, San Antonio, Texas 78295-1540, USATel. (210) 357/4400 Fax: (210) 357/44

Pagina 14

3* Rating Conditions: 80° F. Room Air Temperature and 59% Relative Humidity with 95° F. Outside Air Temperature at 40% Relative Humidity.PERFORMAN

Pagina 15 - HazardGard Cabinet Parts

4COMPRESSOR WINDING TEST(See Figure 2.)Remove the compressor terminal box cover anddisconnect the wires from the terminals. Usingan ohmmeter, check c

Pagina 16 - HazardGard Chassis Parts

5FAN MOTOR (Figure 4)A 230 volt single phase permanent split capacitormotor is used to drive the evaporator blower andcondenser fan. A running capaci

Pagina 17 - ELECTRICAL PARTS

6RED DOTRUN CAPACITORFANMOTORCOMPRESSORFIGURE 6 RUN CAPACITOR HOOK–UPCAPACITOR, RUNA run capacitor is wired across the auxiliary andmain winding of

Pagina 18 - CHASSIS PARTS (Cont.)

7Note: The temperature must be within therange listed to check the thermostat. Refer tothe troubleshooting section in this manual foradditional info

Pagina 19 - OPTIONAL ACCESSORIES

8LOW AMBIENT BY–PASS VALVEThe HazardGard unit is designed to operate atlow outside ambient temperatures. This isaccomplished by the use of a bypass v

Pagina 20 - Use Factory

910.Evacuate the system to an absolute holdingpressure of 200 microns or less.NOTE: This procedure can be speeded up bythe use of heat lamps, or by br

Comentarios a estos manuales

Sin comentarios